Three Phase Microcomputer Relay Protection Tester With High Precision Multi Output
Productdetails
| type | Testmachine | Spanning | Ander |
|---|---|---|---|
| Nauwkeurigheidsklasse | Hoge nauwkeurigheid | Beschermingsklasse | IP55 |
| Plaats van herkomst | China | ondersteuning op maat | OEM, ODM, OBM |
| Maximale uitgangsbelastingsspanning | 20V | Uitgangsvermogen fasespanning/lijnspanning | 70VA/140VA |
| Maximaal uitgangsvermogen van fase-stroom | 450VA | Harmonische frequentie | 0-20 keer (online) 0-6 keer (enkele machine) |
| Nauwkeurigheid van de uitvoer | 0,2 niveau | ||
| Markeren | Three Phase relay protection tester,High Precision relay protection tester,Multi Output 3 phase relay tester |
||
Productomschrijving
Good Quality High Accuracy Three-phase Relay Protection for Power protection Testing
Technique parameters
AC current output
1. AC current output: Output accuracy: 0.2 level
2. Phase current output (effective value): 0-40A
3. Three parallel current output (effective value): 0-120A
4. Long term allowable operating value (effective value) of phase current: 10A
5. Maximum output power of phase current: 450VA
6. Maximum output power at maximum output of triple current: 900VA
7. Allowable working time for maximum output of triple current: 10s
8. Frequency range (fundamental) 0-1000Hz (online) 0-300Hz (standalone) Harmonic order 0-20 times (online) 0-6 times (single machine)
DC current output
1. Output accuracy: Level 0.5
2. Current output: 0~± 10A per phase, 0~± 30A per triple junction
3. Maximum output load voltage: 20V
AC voltage output
1. Output accuracy: 0.2 level
2. Phase voltage output (effective value): 0-120V
3. Line voltage output (effective value): 0-240V
4. Phase voltage/line voltage output power: 80VA/100VA
5. Frequency range (fundamental): 0-1000Hz (online) 0-300Hz (standalone)
6. Harmonic frequency: 0-20 times (online) 0-6 times (single machine)
DC voltage output
1. Output accuracy: Level 0.5
2. Phase voltage output amplitude: 0 to ± 160V
3. Line voltage output amplitude: 0 to ± 320V
4. Phase voltage/line voltage output power: 70VA/140VA
Measurement of switch quantity and time
1. Switching input with 8 empty contacts: 1-20mA, 24V
2. Potential contact connection: "0": 0~+6V; “1”:+11 V~ +250V
3. Switching output 4 pairs DC: 220V/0.2A; AC:220V/0.5A
4. Time measurement range: 0.1ms to 9999s, measurement accuracy: 0.1ms
Packaging and delivery
Inner package: aluminum alloy case+foam plate+dust bag Outer packaging: Standard wooden box for import and export Customer OEM packaging is also available
Product Paramenters
![]()
![]()
![]()