Multi Functional SF6 And Oxygen Gas Detector For High Voltage Substation

Plaats van herkomst China vasteland
Merknaam MINGYANG
Modelnummer MY-303
Min. bestelaantal 1
Prijs 1500usd
Verpakking Details Karton
Levertijd 1 week
Betalingscondities L/C, D/A, D/P, T/T, Western Union
Levering vermogen 1000 stks/maand
Productdetails
typer SF6 Lekdetector Doelgas waterstofsulfide
ondersteuning op maat OEM, ODM, OBM, software-reengineering Gas bewaken zwavelhexafluoridegas
Repetitieve prestaties 1% Hersteltijd < 3 seconden
Garantie 1 jaar Meetbereik 0-12000 ppm
Nauwkeurigheid ± (1,5%+5d) Plaats van herkomst Hubei, China
Afzuigsnelheid luchtpomp ≥ 800 ml/min
Markeren

Multi Functional oxygen gas detector

,

High Voltage Substation oxygen gas detector

,

sf6 gas analyser

Laat een bericht achter
Productomschrijving
Multi-functional SF6 and Oxygen Gas Detector for High Voltage Substation
Advanced multi-functional gas detection system designed specifically for monitoring SF6 and oxygen levels in high voltage substation environments, ensuring safety and compliance.
Technical Specifications
Measurement Method NDIR single beam dual wavelength infrared measurement technology
Monitoring Gas Sulfur hexafluoride gas
Measurement Range 0-12000ppm
Resolution 1ppm
Accuracy ± (1.5%+5d)
Repetitive Performance 1%
Air Pump Extraction Speed ≥ 800ml/min
Continuous Working Time ≥ 5 hours
Instrument Start-up Preheating Time ≤ 10 seconds
Corresponding Time < 3 seconds
Recovery Time < 3 seconds
Charging Adapter Specifications DC5V/1A
Surge (Impact) Immunity ± 1.2kV
Environmental Temperature -20 ℃~+50 ℃
Environmental Humidity Relative humidity of 5-95% (non condensing)
Atmospheric Pressure 50kPa~110kPa
Protection Level IP33, double insulation, CAT II standard
External Dimensions Length 250mm * Width 70mm * Height 160mm
Host Weight 1KG
Multi Functional SF6 And Oxygen Gas Detector For High Voltage Substation 0
Multi Functional SF6 And Oxygen Gas Detector For High Voltage Substation 1
Multi Functional SF6 And Oxygen Gas Detector For High Voltage Substation 2