All Products
-
Global Power Solution EngineerStable quality, on-time delivery, reliable long-term partner. -
Gulf Electrical Engineering SeProfessional technology and perfect after-sales service. -
International Power Research LCustomized solution meets our project requirements perfectly. -
South America Electric Power PProfessional team, good communication and stable supply.
Automatic Open Cup Flash Point Tester Touch Screen High Precision Petroleum Oil Flash Point Measuring Equipment
Product Details
| Type | Open Cup Flash Point Tester | Warranty | 2 Years |
|---|---|---|---|
| Customized Support | OEM | Bandwidth | 70MHz |
| Record Length | 2M | Rise Time At BNC(typical) 5ns | 5ns |
| Vertical Resolutior | 8-bit Resolution, All Channel Sampled Simultaneously | Inputs Impendance3pF | 1MΩ+2% 20pF± |
| Probe Attenuation | 1X, 10X | Sampled Simultaneously Inputs Coupling | AC, DC, GND |
| Supported Probe Attenuation Factor | 1X, 10X, 100X, 1000X | Measuring Range | 0-20kΩ |
| Accuracy Class | ±(0.2%RD+0.05%FS) | Operating Temperature | -10~50°c |
| Dimensions | 320mm*240mm*130mm | Minimum Resolution | Min. 0.1 μ Ω |
| Frequency | 50Hz/60Hz | Usage | Testing Machine |
| Measurement Time | Fast, 10~60 Seconds, Continuous Testing Optional | Working Power Supply | Built-in 12.6V/7.8AH Lithium Battery |
| Weight | 6KG | Resolution | 0.1 ℃ |
| Repeatability Test | ±1℃ | Ignition Method | Spark Ignition |
| Operating Humidity | ≤85% | Cooling Method | Natural Cooling |
| Measuring Range | RT~400°C | Accuracy | ±1°C |
| Ignition Mode | Electric Ignition | Power Supply | 220V 50Hz |
| Temperature Detection | Platinum Resistance | Data Storage | 3000 Data Records |
| Cooling Method | Forced Air Cooling | Ambient Temperature | 10~35°C |
| Highlight | Automatic Open Cup Flash Point Tester,Touch Screen Flash Point Measuring Equipment,High Precision Petroleum Oil Tester |
||
Product Description
Automatic Open Cup Flash Point Tester Touch Screen High Precision Petroleum Oil Flash Point Measuring Equipment
Model NO.
MY202
Accuracy Grade
1
Load Way
Electronic Load
Display
Digital
Control
Computer Control
Weight
17kg
Power Source
220V±11V, 50Hz±2.5Hz
Range
40 ~ 400℃
Detection Type
Flash Point or Light
Temperature Test
Platinum Resistance
Accuracy
±1℃
Re
GB3536-2008 (ASTM D92 ), GB/T267-88
Self Check Function
Lift Rod, Stroke, Print, etc.
Power
Less Than 600va
Ambient Temperature
10~35℃
Ambient Humidity
Less Than 90%
Transport Package
Carton
Trademark
MINGYANG
Origin
China
HS Code
903180909
Production Capacity
100 Set Per Week
Product Overview
Advanced automatic open cup flash point tester designed for oil analysis, featuring touch screen operation and integrated testing environment.
Key Features
- High degree of automation: automatic heating, stirring, lifting, cooling, printing, and calibration test results
- Accurate temperature control with strict compliance to national standard requirements
- Automatic test overtemperature stop function
- Comprehensive instrument self-test capability
- Adjustable igniter brightness control
- Large data storage capacity: 3000 analysis and test records (optional)
- Vertical structure test arm lifting mechanism
- Data record printing functionality
- Pre-test method capability for all unknown flash point samples
- High-performance ARM microprocessor with fuzzy PID temperature control technology for uniform and stable heating
- Touch color LCD display for enhanced human-computer interaction
Technical Specifications
| Measuring Range | Room temperature ~400°C, ~350°C |
| Detection Range | Opening flash point or ignition point |
| Temperature Detection | Platinum resistance |
| Accuracy | ±1°C |
| Repeatability Standards | GB/T3536-2008(ASTM D92), GB/T267-88ASTM D93, GB/T261-2008 |
| Display | Touch color LCD display |
| Data Storage | 3000 data records (displayable and printable) |
| Ignition Mode | Electric ignition |
| Cooling Method | Forced air cooling |
| Printer | Dot matrix thermal printer |
| Work Rate | ≤600W, 300W |
| Power Supply | 220V 50Hz |
| Ambient Temperature | 10~35°C |
| Ambient Humidity | ≤85% |
| Weight | Approximately 17kg |
Product Description
1,Very strong function. A dual-purpose machine at the same time determination of flash point and ignition point, and print the test results, with internal clock chip, automatically display the current date, time, power down to keep the.
2,High precision. The temperature error was controlled at 1.5, and the resolution was 0.1.* good repeatability.
3,Test environment in the guarantee.Consistent with GB3536 (ASTM D92) or GB / T 267-88 for continuous measurement of the same samples, both flash point value difference is less than or equal to 4 degrees centigrade.
4,A high degree of automation. Can automatically complete the testing process, automatic cooling, automatic information tips, etc..
Open flash point determination instrument function and performance at home and abroad and the highest level standards, oil, electricity, chemical industry, commodity inspection and other industries to replace imported products of special instruments.
Product Images