All Products
-
Global Power Solution EngineerStable quality, on-time delivery, reliable long-term partner. -
Gulf Electrical Engineering SeProfessional technology and perfect after-sales service. -
International Power Research LCustomized solution meets our project requirements perfectly. -
South America Electric Power PProfessional team, good communication and stable supply.
Fully Automatic Tan Delta Tester High Precision Anti-interference Dielectric Loss Power Factor Test Set
Product Details
| Type | Testing Machine | Voltage | 220V Electrical Equipment |
|---|---|---|---|
| Accuracy Class | High Accuracy | Power | Electronic |
| Warranty | 2 YEARS | Protection Class | IP65 |
| Place Of Origin | Hubei, China | Application | Auto Testing, Electrical Testing |
| Highlight | High Precision Hipot Tester,Dielectric Loss Tester IP65,Anti Interference Hipot Tester |
||
Product Description
Fully Automatic Tan Delta Tester High Precision Anti-interference Dielectric Loss Power Factor Test Set
Product Description
Product overview
Dielectric Loss Measurement is very basic insulation testing method which can effectively found the deterioration damp deterioration of electrical equipment insulation, as well as local defects. In electrical manufacturing, electrical equipment installation, transfer and preventive tests are widely used. Measuring dielectric loss of transformers, CT/PT, reactors, capacitors, and bushings, surge arresters and other is the most basic measure of its insulating properties. HTJS-M tan delta tester breaks the traditional bridge measurement method, using variable frequency power supply technology, using SCM, and modern electronic technology for automatic frequency conversion, analog / digital conversion and data operations. With strong anti-jamming capability, fast test speed, high precision, automatic digitization, easy to operate; use switching power supply, 45Hz and 55Hz pure sine wave output, automatic apply voltage, providing a voltage up to 10 kV; automatically filter 50Hz interference, suit for substation and other strong electromagnetic interference field testing. Widely used in the power industry transformers, CT/PT, bushings, capacitors, surge arresters and other dielectric loss measurement equipment.
Products features
1.The tester adopts complex current method, which measuring capacitance, dielectric loss, and other parameters. High accuracy of test results, easy to realize automated measurement.
2.The tester adopts frequency technology to eliminate the scene 50Hz frequency interference, even under the condition of strong electromagnetic interference, can get reliable data.
3.Adopts large-screen LCD display, easy to operate.
4.Measurement process is controlled by a microprocessor, as long as to choose correct measurement method, measurement data can be automatically finished under microprocessor control.
5.Integrated design, built-in standard capacitor and HV power supply, convenient for field test, reduce field wiring.
6.High accuracy. Equipped with standard oil cups and dedicated test lines can realize oil dielectric loss measurement.
7.Set CVT test function, can achieve CVT self-excited method test, without external attachments, only need to test one time, capacitance and dielectric loss of C1, C2 can all be measured.
8.Reverse wiring test uses ivddv technology, eliminating the previous reverse wiring data instability phenomenon.
9.With reverse wiring LV shielding function, under the condition of 220 kV CVT busbar grounding, can measure reverse wiring dielectric loss for C11 without dismantling wire 10KV.
10.With measuring HV dielectric loss function, can use HV transformer or series resonance to carry out exceed 10kV voltage dielectric loss test.
11.With ground protection and over-current protection functions.
12.With leakage current protection function, the equipment will instantly cut off high-voltage output to protect operators from electrical hazards.
Dielectric Loss Measurement is very basic insulation testing method which can effectively found the deterioration damp deterioration of electrical equipment insulation, as well as local defects. In electrical manufacturing, electrical equipment installation, transfer and preventive tests are widely used. Measuring dielectric loss of transformers, CT/PT, reactors, capacitors, and bushings, surge arresters and other is the most basic measure of its insulating properties. HTJS-M tan delta tester breaks the traditional bridge measurement method, using variable frequency power supply technology, using SCM, and modern electronic technology for automatic frequency conversion, analog / digital conversion and data operations. With strong anti-jamming capability, fast test speed, high precision, automatic digitization, easy to operate; use switching power supply, 45Hz and 55Hz pure sine wave output, automatic apply voltage, providing a voltage up to 10 kV; automatically filter 50Hz interference, suit for substation and other strong electromagnetic interference field testing. Widely used in the power industry transformers, CT/PT, bushings, capacitors, surge arresters and other dielectric loss measurement equipment.
Products features
1.The tester adopts complex current method, which measuring capacitance, dielectric loss, and other parameters. High accuracy of test results, easy to realize automated measurement.
2.The tester adopts frequency technology to eliminate the scene 50Hz frequency interference, even under the condition of strong electromagnetic interference, can get reliable data.
3.Adopts large-screen LCD display, easy to operate.
4.Measurement process is controlled by a microprocessor, as long as to choose correct measurement method, measurement data can be automatically finished under microprocessor control.
5.Integrated design, built-in standard capacitor and HV power supply, convenient for field test, reduce field wiring.
6.High accuracy. Equipped with standard oil cups and dedicated test lines can realize oil dielectric loss measurement.
7.Set CVT test function, can achieve CVT self-excited method test, without external attachments, only need to test one time, capacitance and dielectric loss of C1, C2 can all be measured.
8.Reverse wiring test uses ivddv technology, eliminating the previous reverse wiring data instability phenomenon.
9.With reverse wiring LV shielding function, under the condition of 220 kV CVT busbar grounding, can measure reverse wiring dielectric loss for C11 without dismantling wire 10KV.
10.With measuring HV dielectric loss function, can use HV transformer or series resonance to carry out exceed 10kV voltage dielectric loss test.
11.With ground protection and over-current protection functions.
12.With leakage current protection function, the equipment will instantly cut off high-voltage output to protect operators from electrical hazards.
Basic Info.
Model NO.
MY-380
Voltage Range
0.5-10kv
Internal Hv
3PF~60000PF/10kv 60PF~1μf/0.5kv
Power
2kVA
Maximum Output Current
200mA
Frequency Accuracy
±0.01Hz
Input Power
180V~270VAC,50Hz
Computer Interface
Standard RS232 Interface
Temperature
-10~50
External Hv
3PF~1.5μf/10kv 60PF~30μf/0.5kv
Resolution
Max: 0.001PF,4 Digits
Tgδrange
Unlimited, Resolution of 0.001%
Test Frequency
45,50,55,60,65Hz
Measuring Time
About 40 S
Relative Humidity
<90%
Transport Package
Wooden Case or Carton
Specification
460*360*350mm3
Trademark
MINGYANG
Origin
China
HS Code
9030849000
Production Capacity
200 Sets Per Month
Technical Specifications
| Accuracy | Cx | ±(reading×1%+1pF) | |
| tgδ | ±(reading×1%+0.00040) | ||
| Anti-interference index | variable-frequency anti-interference, under 200% interference can still achieve the above accuracy | ||
| Capacitance Range | internal HV | 3pF~60000pF/10kV 60pF~1μF/0.5kV | |
| external HV | 3pF~1.5μF/10kV 60pF~30μF/0.5kV | ||
| resolution | Max: 0.001pF,4 digits | ||
| tgδrange | Unlimited, resolution of 0.001%, automatically identify the tested samples of capacitance, inductance and resistance. | ||
| Test CurrentRange | 10μA~1A | ||
| Power | 2kVA | ||
| Internal HV | Voltage range | 0.5~10kV | |
| Max output current | 200mA | ||
| Step-up and step-down voltage mode | Continuous smooth adjustment | ||
| Test Frequency | 45,50,55,60,65Hzsingle-frequency 45/55Hz,55/65Hz,47.5/52.5Hz automatic dual variable-frequency |
||
| Frequency Accuracy | ±0.01Hz | ||
| External HV | When forward wiring the max test current is 1A, power frequency or variable frequency is 40-70Hz | ||
| When reverse wiring the max test current is 10kV/1A, power frequency or variable frequency is 40-70Hz | |||
| CVT self-excited method low voltage output | Output voltage 3 ~ 50V, output current 3 ~ 30A | ||
| Measuring time | About 40 s, correlate with the measurement mode | ||
| Input Power | 180V~270VAC,50Hz±1% | ||
| Computer Interface | Standard RS232 interface | ||
| Printer | A7 thermal mini printer | ||
| Temperature | -10ºC~50ºC | ||
| Relative Humidity | <90% | ||
| Dimension | 460×360×350mm3 | ||
| Weight | 28kg | ||
Important Note: On-site transformer housing is generally grounded. When testing the tanδ (dielectric loss) of transformers, the reverse connection method is generally selected. Only for fully insulated transformers is the forward connection method used for testing.
Capacitance Conversion Reference:
1F = 1000mF = 1,000,000,000μF = 1,000,000,000,000pF
1mF = 0.001F = 1000μF = 1,000,000,000pF
1μF = 1,000,000pF = 0.000001F
1F = 1000mF = 1,000,000,000μF = 1,000,000,000,000pF
1mF = 0.001F = 1000μF = 1,000,000,000pF
1μF = 1,000,000pF = 0.000001F
Product Images
Recommended Products