Portable Fully Automatic Gas Chromatograph for Dissolved Gas Analysis of Transformer Insulating Oil
Product Details
| Type | Testing Machine | Accuracy Class | High Accuracy |
|---|---|---|---|
| Protection Class | IP65 | Customized Support | OEM, ODM, OBM |
| Application | Auto Testing, Electrical Testing | Voltage | 380 V, 220 V |
| Warranty | 2 Years | Power | 300W |
| Place Of Origin | Hubei, China | Output Current AC | 0~20A |
| Utmost Output Capacity | 3*300VA | Display | 192*64 LCD |
| Three Phase Coarse Tuning | 0°~360°, 300 Phase Shifting Each Step. | Temperature Rise | < 60℃ |
| Insulation Resistance | No Less Than 22MΩ | Accuracy | ±1% |
| Phase Of Output | Single-phase | Max. Output Current | 1A Single Piece (could Be Customized) |
| Regulating Range Of Frequency | 30Hz-300Hz | Max. Output Voltage | 300kV (could Be Customized) |
| Insulation Level | Under 1.1 Times And Keeping 1 Min, Normal | Noise Level | No More Than 65dB |
| Temperature Control Area | 6 Loops | Programmed Temperature Order | 16 |
| External | 4 Loops | Dimension | Fid, Tcd, Ecd, Fpd, Npd (Optional) |
| Number Of Detectors | >40db | Start Sampling | Manual, Auto |
| Highlight | portable automatic gas chromatograph,gas chromatograph for transformer oil,dissolved gas analysis chromatograph |
||
Product Description
Portable Fully Automatic Gas Chromatograph for Dissolved Gas Analysis of Transformer Insulating Oil
Advanced portable testing instrument designed for comprehensive analysis of transformer oil and insulating oil through chromatography and dissolved gas analysis.
Basic Info.
Model NO.
MY DGA
Temperature Control Area
6 Loops
Temperature Control Range
Room Temperature: +5~400
Programmed Temperature Order
16
External
4 Loops
Number of Detectors
Fid, Tcd, Ecd, Fpd, Npd (Optional)
Start Sampling
Manual, Auto
Transport Package
Wooden Case or Carton
Specification
see details
Trademark
MINGYANG
Origin
China
HS Code
9030849000
Production Capacity
200 Sets Per Month
Product Description
Product overview
MY DGA adopts the isolated and analysis techniques of multicomponent mixture. It mainly makes use of the differences in the samples of the component boiling point, polarity and the adsorption coefficient in the chromatographic column, to make the components isolated in the chromatographic column, and qualitative and quantitative analyze the isolated components.
UHV-645 oil chromatographic analyzer in accordance with the power system, "insulating oil dissolved gas component content mensuration (chromatography)" requirement, uses micro-computer control, full keyboard, large screen LCD display, with high precision, stable and reliable performance, high sensitivity, good repeatability etc.
The instrument uses two columns in parallel shunt system. Equipped with TCD and double FID and methane reformer, one sample injection can achieve full analysis of seven components of the oil dissolved gas (H2, CH4, C2H2, C2H4, C2H6, CO, CO2), if necessary can do full analysis of nine components (H2, O2, N2, CH4, C2H2, C2H4, C2H6, CO, CO2)
Products features
1.Using advanced technology 10 / 100M adaptive Ethernet communication interface, and built-in IP protocol stack, can easily through the enterprise intranet and Internet for remote data transmission; Convenient for laboratory construction, simplify the laboratory configuration, convenient for management of data analysis
2. The Internal of instrument designed three separated connection process, can connect to the local processing site (laboratory), unit director (such as quality inspection chief, production factory director, etc.), and higher authorities (e.g., environmental protection bureau, bureau of technical supervision, etc.). Can easy to real-time monitor the operation of the instrument and the analysis of data results
3. Optional NetChromTM workstation can simultaneously support multiple chromatographic analyzer work, data processing and control, simplifies document management, and reduces the user's investment and operating costs
4. System with Chinese and English operating system, the user can switch according to their needs
5. Temperature control area can be freely named by the user, convenient for use.
6.The instrument uses the multi-processor parallel work mode, stable and reliable; can meet the complex sample analysis, can optional high-performance detectors, such as FID, TCD, ECD, FPD and NPD, can be installed four detectors at the same time.
7. Adopts the modular structure, design and clear, easy to replace and upgrade, to protect the effectiveness of investments
8.The new microcomputer temperature control system, high precision temperature control, superior reliability and anti-jamming performance; with six fully independent temperature control system can be realized 16 stages temperature programming, so the device is qualified for a wider range of sample analysis; with oven automatic back opening door system, the low temperature control accuracy is improved, up / cool down faster
9. Can optional advanced electronic flow controller (EFC), electronic pressure controller (EPC), to realize the digital control, can greatly improve the reproducibility of qualitative and quantitative results
10. With timing self-starting program, it can easily complete on-line analysis of gas samples (equipped with on-line automatic sample parts required)
11. Full computer control keyboard operating system, simple operation, and design a detector with automatic identification technology. With fault diagnosis, and power-off data protection function, automatic memory setting parameters
12. Built-in low noise, high-resolution 24 AD circuit, and with the function of baseline storage and baseline deduction
13. Chromatographic signals acquisition and data processing, suitable for WinXP, Win2000, Windows7 operating systems. In line with the A / A (USA Analysis Society) standard CDF file is read into the sampling data, it can be integrated with Agilent, Waters and other chromatography workstation
14. The chromatographic system with completely independent intellectual property rights, with the MODBUS/TCP standard interface, easy for docking DCS
15. The device can be docked with many of automatic samplers; such as Shimadzu AOC-20i, Italy HTA company's HT series high-performance liquid, gas auto-sampler, etc
MY DGA adopts the isolated and analysis techniques of multicomponent mixture. It mainly makes use of the differences in the samples of the component boiling point, polarity and the adsorption coefficient in the chromatographic column, to make the components isolated in the chromatographic column, and qualitative and quantitative analyze the isolated components.
UHV-645 oil chromatographic analyzer in accordance with the power system, "insulating oil dissolved gas component content mensuration (chromatography)" requirement, uses micro-computer control, full keyboard, large screen LCD display, with high precision, stable and reliable performance, high sensitivity, good repeatability etc.
The instrument uses two columns in parallel shunt system. Equipped with TCD and double FID and methane reformer, one sample injection can achieve full analysis of seven components of the oil dissolved gas (H2, CH4, C2H2, C2H4, C2H6, CO, CO2), if necessary can do full analysis of nine components (H2, O2, N2, CH4, C2H2, C2H4, C2H6, CO, CO2)
Products features
1.Using advanced technology 10 / 100M adaptive Ethernet communication interface, and built-in IP protocol stack, can easily through the enterprise intranet and Internet for remote data transmission; Convenient for laboratory construction, simplify the laboratory configuration, convenient for management of data analysis
2. The Internal of instrument designed three separated connection process, can connect to the local processing site (laboratory), unit director (such as quality inspection chief, production factory director, etc.), and higher authorities (e.g., environmental protection bureau, bureau of technical supervision, etc.). Can easy to real-time monitor the operation of the instrument and the analysis of data results
3. Optional NetChromTM workstation can simultaneously support multiple chromatographic analyzer work, data processing and control, simplifies document management, and reduces the user's investment and operating costs
4. System with Chinese and English operating system, the user can switch according to their needs
5. Temperature control area can be freely named by the user, convenient for use.
6.The instrument uses the multi-processor parallel work mode, stable and reliable; can meet the complex sample analysis, can optional high-performance detectors, such as FID, TCD, ECD, FPD and NPD, can be installed four detectors at the same time.
7. Adopts the modular structure, design and clear, easy to replace and upgrade, to protect the effectiveness of investments
8.The new microcomputer temperature control system, high precision temperature control, superior reliability and anti-jamming performance; with six fully independent temperature control system can be realized 16 stages temperature programming, so the device is qualified for a wider range of sample analysis; with oven automatic back opening door system, the low temperature control accuracy is improved, up / cool down faster
9. Can optional advanced electronic flow controller (EFC), electronic pressure controller (EPC), to realize the digital control, can greatly improve the reproducibility of qualitative and quantitative results
10. With timing self-starting program, it can easily complete on-line analysis of gas samples (equipped with on-line automatic sample parts required)
11. Full computer control keyboard operating system, simple operation, and design a detector with automatic identification technology. With fault diagnosis, and power-off data protection function, automatic memory setting parameters
12. Built-in low noise, high-resolution 24 AD circuit, and with the function of baseline storage and baseline deduction
13. Chromatographic signals acquisition and data processing, suitable for WinXP, Win2000, Windows7 operating systems. In line with the A / A (USA Analysis Society) standard CDF file is read into the sampling data, it can be integrated with Agilent, Waters and other chromatography workstation
14. The chromatographic system with completely independent intellectual property rights, with the MODBUS/TCP standard interface, easy for docking DCS
15. The device can be docked with many of automatic samplers; such as Shimadzu AOC-20i, Italy HTA company's HT series high-performance liquid, gas auto-sampler, etc
Technical Specifications
| Parameter | Specification |
|---|---|
| Operating Display | 192*64 lattice sinicized liquid crystal |
| Temperature Control Zones | 6 routes |
| Temperature Range | Indoor temperature +5℃~400℃, increment: 1℃, precision: ±0.1℃ |
| Temperature Program Steps | 16 steps |
| Heating Rate | 0.1~40℃/min |
| Pneumatic Control | Mechanical valve control mode or electronic pressure flow control mode (optional) |
| External Events | 4 routes |
| Sample Injector Types | Fill column, capillary, six way valve gas injection, automatic headspace injection, etc. (optional) |
| Detection Configuration | 5 entries: FID, TCD, ECD, FPD, NPD (optional) |
| Sample Start | Manual or automatic (selectable) |
| Communication Port | Ethernet: IEEE802.3 |
System Components & Dimensions
Main Unit: Gross weight: 59kg, Dimensions: 70*60*65cm³
Oscillation Device: Gross weight: 42kg, Dimensions: 61*46*57cm³
Air Gas Generator: Gross weight: 42kg, Dimensions: 65*40*77cm³
Hydrogen Generator: Gross weight: 21kg, Dimensions: 53*36*55cm³
Gas Cylinders: Gross weight: 17kg, Dimensions: 96*21.5*21.5cm³