MY-121 VT CVT CCVT PT Comprehensive Characteristic Analyzer | Electromagnetic & Capacitive Voltage Transformer Testing Equipment

Place of Origin China Mainland
Brand Name MINGYANG
Model Number MY-121
Minimum Order Quantity 1
Price 5000usd
Packaging Details carton
Delivery Time 1 week
Supply Ability 500/Month
Product Details
Types Automatic Type Universal Testing Machine
Loading Method Static Load Load Way Electronic Load
Control Mode Computer Control Display Mode Digital Display
Accuracy Grade 0.05 Max Mass Of Workpiece 20kg
Max Diameter Of Workpiece <500mm Power Supply AC220V
Output Voltage 180V Net Weight 20kg
Overall Dimension 700mm*590mm*350mm Monthly Production Capacity 500 Sets
Input Voltage Range 200VAC~240VAC Allowable Input Voltage 180VAC~260VAC
Frequency 50Hz/60Hz Allowable Frequency Range 45Hz~65Hz
Standby Power 80VA Rated Test Power 600VA
Peak Power 1800VA High Voltage Output 0~3000VAC
Low Voltage Output 0~120VAC,0~120VDC Load Test Resolution 0.02VA
Typical Load Test Accuracy 0.05% Guaranteed Load Accuracy 0.1% ± 0.02VA
Working Temperature -10℃~50℃ Storage Temperature -25℃~70℃
Leave a Message
Product Description

MY-121 VT CVT CCVT PT Comprehensive Characteristic Analyzer | Electromagnetic & Capacitive Voltage Transformer Testing Equipment


 Product Description

MY-121 PT analyzer is a comprehensive test instrument based on transformer volt ampere characteristics ratio regulator, analysis error of comprehensive test instrument transformer volt ampere characteristics of series resonant polarity ratio, widely listen to the views of users, through a new generation of innovative PT test equipment R & D after extensive market research, in-depth theoretical research.

Device adopts high performance DSP+FPGA and ARM industrial computer, advanced manufacturing technology, to ensure stable and reliable product performance, complete functions, high degree of automation, high testing efficiency, in the domestic leading level, is professional testing instrument for transformer in electric power industry.
 

Basic Info.

Model NO.
MY-121
Max Diameter of Workpiece
<500mm
Mass Scope of Workpiece
20kg
Type
Universal Testing Machine
Accuracy Grade
0.05
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Control
Computer Control
Weight
20kg
Power Source
AC220V
Power Supply
220V 50Hz
Voltage Output
180V
Size
365 mm*290mm*153mm
Manufacturer
MINGYANG
Transport Package
Aluminum Alloy Packing Box Inside Andwooden Box O
Trademark
MINGYANG
Origin
China
HS Code
9031809090
Production Capacity
500/Month
Product Features
1: Single instrument can realize the error test of voltage transformer, no need of resonance booster device, standard voltage transformer, load box, check instrument and other equipment, greatly reducing the workload of the field calibration error.

2: The test range is wide, can test the voltage level of 6kV~800kV electromagnetic voltage transformer.

3: Using internal 0.01 level standard voltage transformer, low voltage transformer error measuring by difference test method, and using different frequency measurement technology, nonlinear error of PT conversion 50Hz, finally get the error of transformer. Instrument test level can reach 0.05 level. During the testing process, the maximum generation of test voltage is not more than 3kV, to ensure the safety of the field test.

4: The test wiring ,operation is simple and easy to learn, just according to the guide prompt operation can easily complete transformer calibration work greatly improve the test efficiency. Test time is short, less than 5 minutes.

5: The software algorithm is accurate, the accuracy of measurement data to further improve the intelligent judgment connection status, prompt connection error, wrong polarity ratio, etc..

6: Automatic test data for the whole, and to determine whether the ultra poor, super bad data using anti black display, the data characteristics of the mutual inductor intuitive and clear.

7: Large memory can store the test data of up to 10000.

8: The use of aluminum chassis, with good anti-interference, and to ensure the safety of the operation personnel and equipment safety in the field of high voltage test.

9: Using high resolution and large size 8 inch true color liquid crystal display, outdoor strong light under the clear display, with touch screen auxiliary operation, simple and quick, full Chinese display operation, easy to understand.
Product Parameters

Power Supply
Voltage range 200VAC~240VAC
Allowable voltage range 180VAC~260VAC
Frequency 50Hz/60Hz
Allowable frequency range 45Hz~65Hz
Input power Standby: 80VA  Rated test power:600VA  Peak power:1800VA
Output
High voltage output 0~3000VAC
Low voltage output 0~120VAC,0~120VDC
Output current 0~5A eff(15A peak)
Output power 0~600VA eff(1500VA peak)
Electromagnetic voltage transformer(VT)
Ratio test Ratio:1~350  Voltage level: 0.6kV~35kV Typical accuracy:0.05%
Ratio:350~2450 Voltage level: 35kV~245kV Typical accuracy:0.05%
Phase error test Ratio:1~350  Voltage level : 0.6kV~35kV Typical accuracy:1min
Ratio:350~2450  Voltage level: 35kV~245kV Typical accuracy:2min
Capacitor voltage transformer(CVT/CCVT)
Ratio test Ratio:300~8000 Voltage level: 30kV~800kV Typical accuracy:0.07%
Phase error test Ratio:300~8000 Voltage level: 30kV~800kV  Typical accuracy:2min
Coil resistance measurement
Resolving power 1mΩ
Typical accuracy 0.05%
Guaranteed accuracy 0.1% + 1mΩ
Load test
Resolving power 0.02VA
Typical accuracy 0.05%
Guaranteed accuracy 0.1% + 0.02VA
Size
Volume 700mm*590mm*350mm
Weight 15kg ( No accessories included)
Environment condition
Working temperature -10ºC~50ºC
Storage temperature -25ºC~70ºC
Relative humidity 5%~95%,No condensation

Product Gallery
MY-121 VT CVT CCVT PT Comprehensive Characteristic Analyzer | Electromagnetic & Capacitive Voltage Transformer Testing EquipmentMY-121 VT CVT CCVT PT Comprehensive Characteristic Analyzer | Electromagnetic & Capacitive Voltage Transformer Testing EquipmentMY-121 VT CVT CCVT PT Comprehensive Characteristic Analyzer | Electromagnetic & Capacitive Voltage Transformer Testing EquipmentMY-121 VT CVT CCVT PT Comprehensive Characteristic Analyzer | Electromagnetic & Capacitive Voltage Transformer Testing Equipment