Global Power Solution EngineerStable quality, on-time delivery, reliable long-term partner. -
Gulf Electrical Engineering SeProfessional technology and perfect after-sales service. -
International Power Research LCustomized solution meets our project requirements perfectly. -
South America Electric Power PProfessional team, good communication and stable supply.
MY-143 High Precision Low Temperature Constant Temperature Circulating Bath for Laboratory Cooling Heating Test
| Inner Chamber Size(mm) | 200×160×180, 250×200×200, 300×250×200, 300×280×250, 400×300×250 | Chamber Depth(mm) | 180, 200, 200, 250, 250 |
|---|---|---|---|
| Power(W) | 2100W, 2100W, 2500W, 2700W, 3000W | Pump Flow(L/min) | 4, 4, 8, 8, 12 |
| Working Volume(L) | 7.5L, 10L, 15L, 20L, 30L | Opening Size(mm) | 160×120, 180×140, 250×200, 250×220, 350×260 |
| Supply Voltage | AC220V 50HZ | Temperature Control Range | ‑40℃ ~ 100℃ |
| Temperature Resolution | 0.01℃ | Temperature Fluctuation | ±0.03℃ |
| Operating Ambient Temperature | 5℃‑40℃ | Display Mode | LCD Digital Display |
| Defrost Mode | Automatic Compressor Defrost | Timing Range | 1‑9999 Min |
| Warranty Period | 1 Year | Application | Laboratory Constant Temperature Test, External Circulation Temperature Source |
| Highlight | MY-143 laboratory circulating bath,high precision constant temperature bath,low temperature cooling heating test |
||
MY-143 High Precision Low Temperature Constant Temperature Circulating Bath for Laboratory Cooling Heating Test
Product Description
It is widely used in colleges and universities, enterprises quality inspection and production departments of biology, chemical industry, chemistry, pharmaceutical, life science, physical property testing and other industries. It provides users with a field source controlled by cold and heat, with uniform and constant temperature, for constant temperature experiments or tests on experimental samples or products, and can also be used as
A heat source or cold source for direct heating or cooling and auxiliary heating or cooling.
Product Alias
Low Temperature Constant‑Temperature Circulating Bath / Refrigerated Circulating Water Bath / Heating and Cooling Circulator / Laboratory Thermostatic Circulating Bath / Refrigerated Thermostatic Bath / Low Temp Circulating Bath
Features
1. The inner tank is made of 304 stainless steel, and the outer tank is made of high quality steel plate. The shape is beautiful and novel.
2. Intelligent controller, good temperature control effect;
3. The LED large screen digital display shows temperature, time and other parameters
4. The products manufactured by honest enterprises are durable and the parameters are presented without reservation
5. After-sales service is guaranteed, with after-sales service all over the country
6.Provide video instruction to reduce the time for users to read the manual
7.High efficiency fully enclosed compressor refrigeration, fast cooling speed, with overheating overcurrent and other multiple protection.
8.It has the function of power failure recovery. After the external power supply is suddenly lost and then reconnected, the equipment can automatically resume operation according to the original set program
Product Parameters
| product name | Vertical low temperature tank | ||||
| product model | MY-103-4006 | MY-103-4010 | MY-103-4015 | MY-103-4020 | MY-103-4030 |
| Studio size (mm) | 200×160×180 | 250×200×200 | 300×250×200 | 300×280×250 | 400×300×250 |
| Chamber depth (mm) | 180 | 200 | 200 | 250 | 250 |
| power (W) | 2100W | 2100W | 2500W | 2700W | 3000W |
| Pump flow (L/min) | 4 | 4 | 8 | 8 | 12 |
| volume (L) | 7.5L | 10L | 15L | 20L | 30L |
| Opening size (mm) | 160×120 | 180×140 | 250×200 | 250×220 | 350×260 |
| supply voltage | AC220V 50HZ | ||||
| Temperature control range | -40~100ºC | ||||
| temperature resolution | 0.01ºC | ||||
| temperature fluctuation | ±0.03ºC | ||||
| operating ambient temperature | 5ºC~40ºC | ||||
| display mode | A screen of liquid crystals displays | ||||
| Cooling method | voluntarily | ||||
| Compressor defrosting mode | voluntarily | ||||
| Time range | 1~9999 min | ||||
| quality guarantee period | One year | ||||
| after-sale service | Nationwide warranty service | ||||
Application Scenarios
![]()
FAQ
Question 1: Actual temperature cannot reach the set temperature value
Customer: I set the target temperature on the panel, but the real‑time temperature cannot reach preset value and keeps deviating. What should I check?
Manufacturer: First, confirm the liquid medium is filled to the standard liquid‑level mark; too‑low liquid level will reduce heat‑exchange efficiency. Ensure the air‑cooling ventilation grilles on both sides and rear of the unit are not blocked by objects, papers or wall. Check that ambient room temperature is not excessively high. Verify heating or refrigeration function is activated correctly. If deviation still exists, perform temperature offset calibration in system setting menu. Do not disassemble inner chamber without authorization. Contact our technical support if fault persists.
Question 2: External circulation has no liquid output
Customer: I have turned on external circulation function, but no liquid flows out from external circulation ports.
Manufacturer: Make sure the liquid level inside tank is higher than circulation pump inlet. Check that two circulation hoses are correctly installed on outlet and return port, without folding, squeezing or blockage. Confirm circulation pump switch is enabled on control panel. If impurities block pipeline filter screen, clean the filter. Restart equipment and test circulation again. Never run circulation pump under no‑liquid condition to avoid pump damage.
Question 3: Error code pops up after power‑on startup
Customer: The bath powers on normally, but screen shows error code and stops working immediately.
Manufacturer: Cut off power supply completely, wait 3‑5 minutes then restart the machine. Check ventilation openings are unobstructed. Confirm there is no foreign solid debris inside liquid tank. Record the complete error code. If error recurs after reboot, send error code and on‑site photo to our technical team. Do not open internal electric cabinet cover by yourself.
Question 4: Temperature fluctuates violently and cannot keep stable
Customer: The running temperature swings up and down in large range, stable constant‑temperature state cannot be maintained.
Manufacturer: Avoid frequently opening the tank cover during working process; external ambient air will cause temperature drift. Place equipment away from direct sunlight and strong air‑condition wind. Use qualified anti‑freeze heat‑conduction medium; deteriorated or contaminated medium will greatly affect temperature‑control performance. After modifying set parameters, keep system running for enough thermal equilibrium time before reading test data. Do not place heat‑generating objects near bath tank opening.
Question 5: Liquid leakage occurs at pipeline joints or tank edge
Customer: Liquid medium leaks from hose connectors or around tank cover seam.
Manufacturer: Power off the unit and wait for cooling before inspection. Tighten the connecting nuts of circulation hoses. Inspect silicone hoses for aging, crack and abrasion; replace damaged hoses in time. Confirm hose inner diameter matches equipment port size. If leakage comes from inner‑tank welding seam, stop operation and contact after‑sales support.
Question 6: Refrigeration compressor does not start while heating function works normally
Customer: Heating function works fine, but compressor will not start when low‑temperature cooling is required.
Manufacturer: Check whether set temperature is higher than ambient room temperature; compressor will not activate if cooling is not required. Observe system setting to confirm refrigeration function is not manually disabled. After continuous multiple refrigeration cycles, compressor has short‑delay protection, wait several minutes and observe. If compressor still cannot start, stop using and contact technical support for hardware inspection.
Question 7: Display screen is dim or no response after power‑on
Customer: Power indicator light is on, but control screen is dark, buttons fail to respond.
Manufacturer: Confirm power supply voltage matches equipment rated requirement. Check power socket and power cord for poor contact. Reboot instrument by cutting power for 5 minutes. If screen still keeps dark, internal control module may be abnormal, please contact after‑sales service.
Question 8: Shipping Method
Customer: If we place an order, how do you typically ship the goods? Will there be any issues with transporting bulky items such as reactors?
Manufacturer: We default to using dedicated logistics lines or brand-specific express shipping services; small-sized main units and accessories may also be shipped via standard courier services. Large items, such as reactors and excitation transformers, are packed using wooden crates or wooden frames for reinforcement to prevent bumps and moisture exposure during transit; a packing list is included with each package to facilitate item-by-item counting for you. Logistics costs are typically determined by both parties in accordance with the contract terms; after shipment, we will send you both the tracking number and the carrier's contact phone number for easy tracking.If your project site is remote or if delivery to the site is required with a specified logistics company, please inform us in advance when placing your order; we can then coordinate and arrange accordingly.
Question 9: Delivery Lead Time
Customer: Our project is under tight deadlines; how long will it take for the order to be shipped after we place it? Can we request expedited shipping?
Manufacturer: Standard specifications – stock available; typically delivered upon receipt of the order. Orders can be shipped within [X] working days; for non-standard products requiring customized voltage levels, capacities, or reactor combination configurations, the production cycle typically ranges from [X] to [Y] days.The delivery time will be approximately 7-15 working days; the specific timeline shall be subject to the sales confirmation provided upon order placement. If your project has a tight schedule, please inform us of the latest expected delivery date before placing your order; we will first verify the production schedule and inventory status, and where possible, will coordinate expedited production and prioritize shipment. However, it is recommended to allocate sufficient transit time for logistics to avoid delaying on-site testing.
Question 10: After-sales Service and Warranty
Customer: What is the warranty period for this equipment? If any issues arise during on-site use, how will your after-sales service respond?
Manufacturer: We provide a two-year free warranty on the entire unit and lifelong technical support services. During the warranty period, if issues arise due to defects in the equipment itself, we will provide free repair or replacement of components; when problems occur on-site, we commit to responding within 24 hours; most wiring and parameter configuration issues can be resolved through remote guidance via video or telephone; for cases where an on-site visit is necessary, we will arrange for our technicians to arrive at the location to resolve the issue. After the warranty period expires, we still offer repair services, with spare parts supplied at cost price for the long term, and software updates provided free of charge for life. Upon delivery of the equipment, we also offer free operational training (video operation guides)to ensure that your testing personnel can operate the equipment independently and proficiently; should you have any further questions, please feel free to contact our dedicated after-sales hotline directly.
Question 11: Shipping methods for each region (Sea freight)
Customer: Our projects are distributed across several states, and our procurement volumes are substantial; are the shipping methods consistent across all states? How is the delivery time calculated?
Manufacturer: The specifications are identical; however, it should be specifically noted that this equipment set is large in size and heavy in weight—components such as the reactor and excitation transformer are all classified as heavy components. Therefore, regardless of which state or region the shipment is destined for, we will uniformly utilize sea freight transportation. The packaging employs export-grade wooden crates with reinforced structures, along with moisture-proof and rust-proof treatments; the design of these wooden crates is optimized for long-distance sea transport and multiple lifting and transshipment operations. Upon arrival at the destination, simply unpack the goods and conduct an inspection before putting them into use. Regarding delivery time, the sea freight transit period depends on the port of destination: near-sea routes are generally faster, whereas ocean routes may take longer; the exact number of days will be confirmed based on the shipping schedule specified in the bill of lading. We have a dedicated freight forwarding agency to handle booking of shipping space, customs declaration, insurance, and other related procedures; once the vessel departs, we will send you documents such as the bill of lading and the packing list, enabling you to arrange for the receipt of goods at the port of destination and their inland transshipment in advance
Shipping scenario
Scene (One)
![]()
Scene (Two)
![]()
Attachment Directory
| Qty | Item Name | Description |
|---|---|---|
| 1 Set | Main Machine | Low temperature constant‑temperature circulating bath host unit |
| 2 Pcs | Silicone Circulation Hose | For external circulation liquid outlet and return connection |
| 1 Pc | Power Cord | AC power supply cable for equipment power input |
| 1 Pc | Drain Pipe | Used for draining liquid medium inside the tank |
| 1 Pc | User Operation Manual | Instruction for installation, parameter setting and daily maintenance |
| 1 Pc | Factory Calibration Certificate | Factory inspection and calibration document |
Attachment Image
![]()