Hipotmeetapparaat
-
Transformatortester
-
testkit voor secundaire injectie-relais
-
Schakelbreker-analysator
-
SF6 gasanalysator
-
de analysator van de machtskwaliteit
-
batterijmeetapparaat
-
Weerstandsmeetapparaat
-
Kabelfoutzoeker
-
Draadloze fase-detector
-
de kaliberbepalingsmateriaal van de energiemeter
-
CT PT-meter
-
Tester voor overspanningsbeheersing
-
Global Power Solution EngineerStabiele kwaliteit, tijdige levering, betrouwbare langetermijnpartner. -
Gulf Electrical Engineering SeProfessionele technologie en perfecte after-sales service. -
Internationaal Energieonderzoek LDe op maat gemaakte oplossing voldoet perfect aan de eisen van ons project. -
Zuid-Amerika Electric Power PProfessioneel team, goede communicatie en stabiel aanbod.
Portable Transformer Oil BDV Tester Dielectric Strength Analyzer For Insulating Oil
| Meetbereik | 1-1999μΩ | Nauwkeurigheidsklasse | Hoge nauwkeurigheid |
|---|---|---|---|
| Bedrijfstemperatuur | -10 ℃ ~ 40 ℃ | Tijdresolutie | 1S |
| Huidige resolutie | 1μΩ | Plaats van herkomst | Hubei, China |
| Oplossing | 1μΩ | Meetnauwkeurigheid | 0,5% |
| Meetbereik | 1-1999μΩ | Werkende voeding | AC220V ± 10%, 50 Hz ± 1 Hz |
| Gewicht | 12 kg | Weergavemodus | LCD-scherm met drie en een half cijfers |
| Volume | 380*350*260mm | type | Testmachine |
| Beschermingsklasse | IP65 | ondersteuning op maat | OEM |
| Stroom | elektrisch | Garantie | 2 jaar |
| Spanning | 220 V, 110 V | Sollicitatie | Olietesten, olie BDV-tester |
| Plaats van herkomst | Hebei, China | Uitgangsspanning | 0~80KV (optioneel) |
| Vervorming van de spanning | <3% | Producttype | olie bdv-tester |
| Staande tijd | 15min (instelbaar) | Boostercapaciteit | 1.5kVA |
| Meetnauwkeurigheid | ±3% | Toepasselijke temperatuur | 0°C tot 45°C |
| Voedingsspanning | AC220V±10% 50Hz±1 Hz | ||
| Markeren | Portable oil bdv tester,Insulating Oil oil bdv tester,IP65 transformer test kit |
||
The Automatic Oil Dielectric Strength Tester is designed for safe testing of large power transformers and other high-voltage electrical equipment including oil circuit breakers, oil-filled cables, power capacitors, and oil sleeves.
During operation, transformer oil performance gradually deteriorates due to exposure to oxygen, high temperature, humidity, sunlight, strong electric fields, and impurities, compromising its insulation capabilities. This tester accurately identifies performance degradation, as insulation oil quality is directly related to breakdown voltage.
| Parameter | Specification |
|---|---|
| Power Voltage | AC220V ± 10%, 50Hz ± 5% |
| Equipment Capacity | 0.5kVA, Volume Capacity 1.5 kVA |
| Limited Current | 5mA |
| Input Voltage | 200V/50Hz |
| Output Test Voltage | 0-80kV |
| Measurement Range | AC 0-80kV |
| Voltage Indicator Error | ± 5% |
| Breathing Speed | 2kV/second ± 20% |
| Compression Speed | 2kV/s ± 10% |
| State Settings | Number of times 1-9 |
| Static Time | 0-10 minutes 39 seconds |
| Stirring Time | 0-1 minutes 39 seconds |
| Burning Time | ≤ 20ms |
| Measurement Accuracy | 1% |
| Use Conditions | Ambient temperature 10℃ - 35℃ |
| Relative Humidity | ≤ 75% |
| Oil Cup Gap | 2.5mm (diameter of oil cup plug ruler) |
| Breathing Speed Options | 2.0kV/s, 2.5kV/s, 3.0kV/s, 3.5kV/s (four-gear option) |
| Packaging Size & Weight | 48*45*38cm, 25kg |