All Products
-
Global Power Solution EngineerStable quality, on-time delivery, reliable long-term partner. -
Gulf Electrical Engineering SeProfessional technology and perfect after-sales service. -
International Power Research LCustomized solution meets our project requirements perfectly. -
South America Electric Power PProfessional team, good communication and stable supply.
MY-138 Programmable Constant Temperature And Humidity Climatic Test Chamber Environmental Temperature Humidity Cycling Aging Tester
| Temperature Range: | -70℃/-60℃/-40℃/-20℃/0℃~150℃,custom Available |
|---|---|
| Humidity Range: | 20%RH‑98%RH;Custom Low Humidity:10%RH~98%RH /5%RH~98%RH |
| Temperature & Humidity Fluctuation: | ±0.3℃;±0.5%RH |
MY-137 Electromagnetic Vibration Shaker Tester | Touch‑screen Vibration Test System
| Model: | MY-137 |
|---|---|
| Power Supply: | AC 220V / 50Hz ±10% |
| Operating Ambient Temperature: | 0 ~ +40°C |
MY‑134 Portable On‑Load Tap Changer Tester OLTC Analyzer for Transformer Tap Switch Transition Resistance & Action Time Test
| Charging Current Gear: | 3A/1A Gear; 0.6A/0.2A Gear |
|---|---|
| Max Terminal Voltage: | 24V |
| Max Transition Resistance Range: | 100Ω |
MY-136 Dual‑Station Desktop Automatic AB Glue Dispenser, 3‑Axis Epoxy Resin Dispensing Robot
| Working Area(x*y*z)(mm): | 300*300*120mm 400*400*120mm 500*500*120mm |
|---|---|
| Max Weight Bearing: | Y/10KG Z/5KG |
| Moving Speed (mm/s): | 0.1-800 |
MY‑133 Portable Digital Ultrasonic Flaw Detector Handheld NDT Tester with Straight Probe & Angle Probe for Metal Weld Defect Inspection
| Working Principle: | Ultrasonic |
|---|---|
| Working Frequency: | 0.2‑20MHz(MY‑U600); 0.5‑20MHz(MY‑610/MY‑620/MY‑630) |
| Pulse Width: | Square Wave Width 30‑1000ns Adjustable, Step 0.1ns |
MY‑132 Circuit Breaker Analyzer High Voltage Switchgear Tester Circuit Breaker Dynamic Characteristic Test Equipment
| Time Measurement Channels: | 12 Channels |
|---|---|
| Special Channel Function: | 3‑channel For Time Contact & Resistance Contact Time; 6‑channel Isolated Contacts For Pole Cascaded Unit Measurement |
| Time Measurement Range: | 4000ms |
MY‑131 Transformer Turns Ratio & Winding Resistance Tester Portable
| Direct Resistance Test Output Current: | 20A,10A,5A,1A,0.1A,≤10mA |
|---|---|
| Direct Resistance Measuring Range: | 20 A:0.5mΩ‑100mΩ;10 A:1.0mΩ‑300mΩ;5 A:10 mΩ‑1.0 Ω;1 A:200mΩ‑6.0 Ω;0.1 A:2.0 Ω‑60 Ω;≤10mA:30 Ω‑50 kΩ |
| Direct Resistance Test Accuracy: | ±(Reading × 0.2% + 2 Words) |
MY-130 Concrete Freeze Thaw Cycle Test Chamber
| Condenser Cooling Mode: | Air Cooling |
|---|---|
| Accepted Specimens: | 10/16/28 Pcs, Can Be Customized |
| Specimen Size: | 100×100×400mm |
Automatic Anti‑interference Dielectric Loss Tester | High Voltage Tan Delta Test Equipment
| Accuracy (Cx): | ±(reading×1%+1pF) |
|---|---|
| Accuracy (tgδ): | ±(reading×1%+0.00040) |
| Power Measurement Accuracy: | ±(Reading×1.0% +2 Words), 0.2≤cosφ≤1 |